5558 Berkshire Valley Road STE 6
Oak Ridge, NJ 07438
(973) 838-3200

Our Top Cities


Local Reviews
for pequannock township, nj

Rated 5.0 out of 5 stars based on 2 customer reviews

Great job

Jack took his time and did a great job


Response from Climate Plus, LLC:

Thanks Dominick! It is a pleasure to provide you with a great job by Jack! Best, Joseph

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very friendly and was able to identify the problem


Response from Climate Plus, LLC:

We’re delighted to hear about your recent experience with us and we’re so pleased that you recommend our services. Thank you for taking the time to share your experience and we look forward to welcoming you back soon!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pequannock township, nj

Jack B.

Jack B. Job Checkin

Arrived onsite for ac maintenance on 2 systems. Asked customer to turn AC on to confirm operation. Chemically Cleaned outside coils on both systems. Attic unit. Checked all electrical. measured pressures for 410a at 95/195psi with 3 degree sub cooling with outside temperature at 58 degrees. Measured temperature drop at 9 degrees. Cleaned condensate line. Observed sensing dislodged from the unit and exposed to the elements of the attic. I believe it had been like that since it was installed. Changed filter 24x30x1. System running but not very efficiently.

Arrived onsite for ac maintenance on 2 systems. Asked customer to turn AC on to confirm operation. Chemically Cleaned outside coils on both systems. Attic unit. Checked all electrical. measured pressures for 410a at 95/195psi with 3 degree sub cooling with outside temperature at 58 degrees. Measured temperature drop at 9 degrees. Cleaned condensate line. Observed sensing dislodged from the unit and exposed to the elements of the attic. I believe it had been like that since it was installed. Changed filter 24x30x1. System running but not very efficiently.

Joseph C.

Joseph C. Job Checkin

Removed the failed condenser fan motor assembly, picked up a new OEM replacement motor, blade and capacitor. Installed all three components and wired as necessary, started up the system and confirmed operation of the new motor assembly. The new motor is now running and operating properly, checked operation of the system and confirmed that it is currently operating and cooling properly.


Joseph C.

Joseph C. Job Checkin

Started up and checked the refrigerant charge for the system, installed the Measurequick app and confirmed that the unit is low on refrigerant. Added 5lbs of R410a refrigerant, the unit is now cooling properly.

Started up and checked the refrigerant charge for the system, installed the Measurequick app and confirmed that the unit is low on refrigerant. Added 5lbs of R410a refrigerant, the unit is now cooling properly.

Joseph C.

Joseph C. Job Checkin

Removed the failed condenser fan motor assembly, picked up a new OEM replacement motor, blade and capacitor. Installed all three components and wired as necessary, started up the system and confirmed operation of the new motor assembly. The new motor is now running and operating properly, checked operation of the system and confirmed that it is currently operating and cooling properly.


Jack B.

Jack B. Job Checkin

Arrived onsite for maintenance for one gas fired boiler. Requested the customer turn on the thermostats up to heat and confirm operation of the boiler and each zone valve. Turned the boiler off and removed and cleaned all burners and wiped cleaner the burner compartment. Performed a visual inspection of all electrical and inspected all external water components such as the exp tank, fill valve, backflow preventer and the circulator pump. Completed combustion test. Observed over 20 psi of boiler water pressure. Reduced to about 18 pounds of pressure. Didn’t observe a swishing sound indicating water in the line but did hear slight knocking. Reducing the pressure may reduce the knocking sound. System is otherwise operating as it should.

Arrived onsite for maintenance for one gas fired boiler. Requested the customer turn on the thermostats up to heat and confirm operation of the boiler and each zone valve. Turned the boiler off and removed and cleaned all burners and wiped cleaner the burner compartment. Performed a visual inspection of all electrical and inspected all external water components such as the exp tank, fill valve, backflow preventer and the circulator pump. Completed combustion test. Observed over 20 psi of boiler water pressure. Reduced to about 18 pounds of pressure. Didn’t observe a swishing sound indicating water in the line but did hear slight knocking. Reducing the pressure may reduce the knocking sound. System is otherwise operating as it should.

Jack B.

Jack B. Job Checkin

Arrived onsite for maintenance of high efficiency boiler. Requested the customer turn on the thermostats up to heat and confirm operation of the boiler and each zone valve. Turned the boiler off and wiped cleaner the burner compartment: performed a visual inspection of all electrical and inspected all external water components such as the exp tank, fill valve, backflow preventer and the circulator pump. System working as it should. As per homeowners request set clock back for daylight savings time.

Arrived onsite for maintenance of high efficiency boiler. Requested the customer turn on the thermostats up to heat and confirm operation of the boiler and each zone valve. Turned the boiler off and wiped cleaner the burner compartment: performed a visual inspection of all electrical and inspected all external water components such as the exp tank, fill valve, backflow preventer and the circulator pump. System working as it should. As per homeowners request set clock back for daylight savings time.

Jack B.

Jack B. Job Checkin

Looking for efficient EPP maintenance services with no timing constraints? Trust us for top-notch 1C maintenance where customers provide filters. Enjoy expert service that prioritizes quality and convenience every step of the way.


Cole D.

Cole D. Job Checkin

Experience top-notch maintenance with Comfort Club 2C from Climate Plus LLC! Ensure your morning arrival is comfortable with our expert maintenance services. Customer's filters are on-site and aware of costs. Contact us for more information on partnering plans. Customer also noted a new generator connected to the HVAC system - we've got you covered.


Jack B.

Jack B. Job Checkin

3-6 roughly Arrival; PLEASE BRING STONES THAT DOMINICK PAID FOR IN THE PAST AND WE NEVER BROUGHT


Jack B.

Jack B. Job Checkin

For fast and reliable residential AC repair and installation services, contact Climate Plus LLC. With flexible scheduling and no arrival time, you can trust us to be there before 5. Schedule an appointment set by our team member Tiffany today.


Jack B.

Jack B. Job Checkin

Repair zone control and replaced zone dampers restoring 2 zone heating for this gas fired boiler

Repair zone control and replaced zone dampers restoring 2 zone heating for this gas fired boiler

Jack B.

Jack B. Job Checkin

Repair zone control and zone dampers to bring 2 zone heating for this gas fired boiler


Jack B.

Jack B. Job Checkin

Performed annual preventive maintenance on Slant Fin Gas Fired Boiler

Performed annual preventive maintenance on Slant Fin Gas Fired Boiler

Joseph C.

Joseph C. Job Checkin

A new NTI high efficiency combination boiler installation

A new NTI high efficiency combination boiler installation

Jack B.

Jack B. Job Checkin

No heat on Amana Gas Fired Furnace

No heat on Amana Gas Fired Furnace